2 - ADTRAN 908E
Point to Point
T1 Sprint
I am using my RDP connection and connection to an external IP address. When I am connected for about 10 seconds, the RDP looses connection and try's to reconnect. This happens the entire session, every ten seconds it pops up. I am able to connect and and stay connected if not using the ADTRANS. I have tested IPCONFIG trace with no disconnect of traffic.
Is there a setting change I need to make to the adtrans to make the connection stable for RDP?
Message was edited by: David Shirley
After a day of testing and troubleshooting I have found the failure point.
COMPUTER -> Adtran (1) -> Adtran (2) -> GW -> Internet -> Sonicwall -> COMPUTER (RDP)
This route connects but loses connection every 45 seconds.
To test where failure point is------------------------->>>>>>>>>
If I remove the Sonicwall I connect with no disconnect.
COMPUTER -> Adtran (1) -> Adtran (2) -> GW -> Internet -> COMPUTER (RDP)
If I remove the Adtrans I connect with no disconnect
COMPUTER -> GW -> Internet -> Sonicwall -> COMPUTER (RDP)
So I feel the Sonicwall has something to do with the disconnects when using it through the Adtrans
Any ideas?
How is your T-1 clocked? If it's a point-to-point, one of the Adtrans should be configured with timing source internal and the other to timing source t1 0/1 (or whichever T1 interface is connected to the other one. It doesn't matter which is which unless there is more than one T-1 involved. Then it can get interesting.
Clocking issues are a common T-1 configuration issue.
T-1 circuits need one and exactly one end of the circuit to generate timing, and the other to recover from the T1 line.