I have a strange voice quality issue off an AdTran 924e 2nd Gen running OS ADTRAN, Inc. OS version A4.09.00.E. We have replaced the device to rule out the issue, however it still occurs. All transport has been tested clean to the customer site. Currently, one voice user on all inbound calls, has a static/robotic sound, while the voice quality stats show Out of Order packets incrementing by the hundreds. On outbound calls on the same line, the call stays clean for exactly 1 minute 30 seconds, before there is a click, which starts the robotic/static sounding audio, and then starts the incrementing of the out of order packets. This only occurs on one voice user. The issue also follows the voice user and not the fxs port as I remapped it to a spare port and the issue followed. Anyone have any ideas on what could cause such a strange issue?
Below is an output of voice quality stats with the issue occuring:
Start Out of Discard Delay
ID Time From To Length Codec Order Pkts* Avg Max
--------------------------------------------------------------------------------
2 3:40 PM 914xxxxxxx 18666xxxxxxx 27:13 G711u 2 0 50 50
21 4:06 PM 914xxxxxxx 1516xxxxxxx 1:36 G711u 541 0 54 100
22 4:06 PM 914xxxxxxx 1800xxxxxxx 1:13 G711u 0 0 50 50
Thanks,
Chris
This issue has been resolved. This turned out to be a media profile type set incorrectly in our VoIP switch. Thanks for the replies.
Hello,
When you say "one voice user" is that a device registered to the Total Access?
Please explain "outbound calls on the same line".
How are you connecting to the PSTN?
If possible send a basic network diagram.
Thank you,
Hello,
I came across this post and wondered if you still needed assistance. Please let me know if you do and we can work on this.
Regards,
Geoff
This issue has been resolved. This turned out to be a media profile type set incorrectly in our VoIP switch. Thanks for the replies.