How do you enable RTCP report generation on the Total Access 900e Series devices?
I have VQM & SIP RTP monitoring enabled, but it doesn't appear that any RTCP packets are being sent by the TA900e along with the RTP stream.
Does the TA900e support sending RTCP reports along with the RTP stream?
Hello and thank you for posting to our forum.
When turned on, VQM will look at received RTCP but the DSP in the ADTRAN does not send it or look at at. VQM has the ability to export some statistics but there is no way for the TA 900(e)s to do so.
Page 60 in this guide discusses Exporting Stats from VQM:
Configuring Voice Quality Monitoring (VQM) in AOS
Let me know if you have any questions.
Regards,
Geoff
To get a little more specific:
ITSP SBC <--SIP--> TA900e <--PRI--> PBX
I'd like the TA900e to send RTCP reports to the SIP ITSP during the call so that the ITSP's SBC can monitor VoIP quality.
Hello and thank you for posting to our forum.
When turned on, VQM will look at received RTCP but the DSP in the ADTRAN does not send it or look at at. VQM has the ability to export some statistics but there is no way for the TA 900(e)s to do so.
Page 60 in this guide discusses Exporting Stats from VQM:
Configuring Voice Quality Monitoring (VQM) in AOS
Let me know if you have any questions.
Regards,
Geoff
Hello.
I went ahead and flagged the "Correct Answer" on this post to make it more visible and help other members of the community find solutions more easily. If you don't feel like the answer I marked was correct, feel free to come back to this post and unmark it and select another in its place with the applicable buttons. If you still need assistance, we would be more than happy to continue working with you on this - just let us know in a reply.
Regards,