Hello,

I have a network where I want to split out 14 56k DDS circuits that are coming over a T1. The network drawing is attached. I need one standalone TDU 600 unit with 3 quad OCU modules and 1 dual OCU module giving a total of 14 DDS ports for connection to your the DSUs.

I know this is EOL. I'm OK with refurbished gear in this case. Can someone give me a configuration with part numbers of the chassis and modules?

Thanks!

David

0 Kudos
3 Replies
Anonymous
Not applicable

Re: TSU 600 and modules

You will need a TSU 600 product as well as the OCU DP modules.

The TSU 600 has the following models:

TSU 600 (AC power): PN 1202076L2 (2nd Generation) or 1200076L2 (1st Generation)

TSU 600 DC power: 1202076L2#DC (2nd Gen) or 1200076L2#DC (1st Gen)

There is also an "e-series" TSU 600 which has an ethernet port for management purposes (allows telnet access)

TSU 600e (AC): 1202076L1

TSU 600e DC power: 1202076L1#DC

The OCU DP modules are dual-port and come as plug-in or plug-on, so when you put a plug-on module onto a plug-in module you have 4 ports.

So you will need 4 plug-in modules and 3 plug-on modules.

OCU DP Plug-in: 1200230L1

OCU DP Plug-on: 1200231L1

Hope this helps,

Patrick

dstehle
New Contributor

Re: TSU 600 and modules

Thanks for responding!

So:

qty. 1 - TSU 600 (AC power): PN 1202076L2 (2nd Generation) or 1200076L2 (1st Generation)

qty. 4 - OCU DP Plug-in: 1200230L1

qty. 3 - OCU DP Plug-on: 1200231L1

Is there no quad card? I had sometime quote it like this:

"You would need one standalone unit with 3 quad OCU modules and 1 dual OCU module giving you a total of 14 DDS ports for connection to your remote DSUs."

Thanks again.

David

Anonymous
Not applicable

Re: TSU 600 and modules

No, there is no Quad OCU DP card for the TSU series.