Mosaic Cloud TA5000 Onboarding Using Profiles and Profile Vectors

Using the Mosaic CP FTTP Plugin Profiles 2023.1 (TA5000) or the SDX Example Profiles 22.1 (SDX) profiles and profile vectors, we are able to onboard the TA5000 and xPON interface with auto-builders to automatically turn up ONUs and services when the devices send an activation trap.

The following video demonstrates this functionality. A copy/paste version of the onboarding commands used in this process and a full transcript of the commands used to automatically onboard ONUs and services with profile and profile vectors are available below the video.

Copy/paste commands (in order) for Mosaic Cloud Platform onboarding with profiles and profile vectors (PVs)

unzip adtn-ta5k-base-profiles-3.0-27.zip
cd adtn-ta5k-base-profiles
mcp-takeout -u 'ADMIN:P@ssw0rd' -i localhost execute cda/

Mosaic Cloud Platform onboarding with profiles and profile vectors (PVs)Transcript

[root@host-10-255-68-238 opt]# unzip adtn-ta5k-base-profiles-3.0-27.zip
Archive:  adtn-ta5k-base-profiles-3.0-27.zip
   creating: adtn-ta5k-base-profiles/
  inflating: adtn-ta5k-base-profiles/README.md
  inflating: adtn-ta5k-base-profiles/profile_user_guide-version-2022.4.pdf
   creating: adtn-ta5k-base-profiles/cda/
   creating: adtn-ta5k-base-profiles/cda/profiles/
  inflating: adtn-ta5k-base-profiles/cda/profiles/activate
  inflating: adtn-ta5k-base-profiles/cda/profiles/configure
  inflating: adtn-ta5k-base-profiles/cda/profiles/deploy
   creating: adtn-ta5k-base-profiles/cda/vectors/
  inflating: adtn-ta5k-base-profiles/cda/vectors/activate
  inflating: adtn-ta5k-base-profiles/cda/vectors/configure
  inflating: adtn-ta5k-base-profiles/cda/vectors/deploy
[root@host-10-255-68-238 opt]# cd adtn-ta5k-base-profiles
[root@host-10-255-68-238 adtn-ta5k-base-profiles]# mcp-takeout -u 'ADMIN:P@ssw0rd' -i localhost execute cda/
----- Configure profiles -----
Successes:  69
Failures:  0----- Deploy profiles -----
[2023-04-04T17:37:54.864+0000] WARNING [mcp_takeout.utils.actions.execute] - not-started Transition Not Started deploy profiles aes-encryption-profile-type/AES Encryption Enabled Default Profile
        Validation of precondition failed: Profile AES Encryption Enabled Default Profile of type aes-encryption-profile-type does not exist.
[2023-04-04T17:38:08.423+0000] WARNING [mcp_takeout.utils.actions.execute] - not-started Transition Not Started deploy profiles aes-encryption-profile-type/AES Encryption Enabled Default Profile
        Validation of precondition failed: Profile AES Encryption Enabled Default Profile of type aes-encryption-profile-type does not exist.
[2023-04-04T17:38:08.425+0000] WARNING [root] - Couldn't complete restore during this round.details:
    verb - deploy
   actions -
        not-started Transition Not Started deploy profiles aes-encryption-profile-type/AES Encryption Enabled Default Profile
Successes:  69
Failures:  1----- Activate profiles -----
Successes:  69
Failures:  0[2023-04-04T17:38:20.639+0000] ERROR [mcp_takeout.file.cda] -
JSON Loading error from cda/vectors/configure:13
    line: '{"profile-vector-name": Auto Upgrade Device ONU Profiles Vector", "type": "device"}'
    details: Expecting value: line 1 column 25 (char 24)
----- Configure vectors -----
Successes:  13
Failures:  0----- Deploy vectors -----
[2023-04-04T17:38:30.662+0000] WARNING [mcp_takeout.utils.actions.execute] - not-started Transition Not Started deploy vectors Auto Upgrade Device ONU Profiles Vector
        Validation of precondition failed: profile vector with name Auto Upgrade Device ONU Profiles Vector not available'
[2023-04-04T17:38:31.393+0000] WARNING [mcp_takeout.utils.actions.execute] - not-started Transition Not Started deploy vectors Auto Upgrade Device ONU Profiles Vector
        Validation of precondition failed: profile vector with name Auto Upgrade Device ONU Profiles Vector not available'
[2023-04-04T17:38:31.394+0000] WARNING [root] - Couldn't complete restore during this round.details:
    verb - deploy
   actions -
        not-started Transition Not Started deploy vectors Auto Upgrade Device ONU Profiles Vector
Successes:  13
Failures:  1[2023-04-04T17:38:31.395+0000] ERROR [mcp_takeout.file.cda] -
JSON Loading error from cda/vectors/activate:13
    line: '{"profile-vector-name": Auto Upgrade Device ONU Profiles Vector", "type": "device"}'
    details: Expecting value: line 1 column 25 (char 24)
----- Activate vectors -----
Successes:  13
Failures:  0 
[root@host-10-255-68-238 adtn-ta5k-base-profiles]# 