I have 50+ TA9xxe in the field and they are doing SIP to PRI conversion, and all are using T1 interface 0/1 or 0/2, no current complaints or issues that I am aware of. Just getting conflicting information......
Total Access 9XXe - SIP to PRI sample configuration the Sample config shows T1 interface 0/1 used (matches my deployment)
Total Access 900 900e PRI Trunk Quick Configuration Guide the document states "In the TA 900 series, only T1 port 0/2 can be used for a PRI connection. In the TA 900e series, T1 ports 0/3 and 0/4 can be used for PRI connections"
which one is accurate?
If I should be using interface 0/3 and 0/4, why? trying to determine if I need to revisit my existing deployments
Timothy,
Depends on what generation TA900e you have. If you have 2nd Gen (white unit) then only ports 3/4 can be used for PRI interfaces. If you have 3rd gen (Black unit) then 1-4 can be used for PRI interfaces but maximum of 2 can be configured depending on what p/n you ordered regarding number of DSPs, we sell a 30 and 60 count version.
If you do a show version it will show you have many you have like so:
Tiger#show version
ADTRAN, Inc. OS version R13.2.2.E
Mainline Version: ENM.17.94
P4 Changelist: 651357
Checksum: ccd996184c9dfa18573d4fbd589120e70d648470dd614b267ba6b072e7f8dcdd
Built on: Mon Aug 6 05:34:43 CDT 2018
Hardware version L.1.5.0.0-0
Boot ROM version R10.9.3.B1
Built on: Fri Apr 11 09:42:09 CDT 2014
Compatibility Version: 1
Copyright (c) 1999-2018, ADTRAN, Inc.
Platform: Total Access 908e (3rd Gen), part number 4243908F5
Serial number CFG1384365
Flash: 97120256 bytes DRAM: 509648896 bytes
Tiger uptime is 3 weeks, 3 days, 5 hours, 35 minutes, 53 seconds
slot 0, DSP 1
DSP software version: G3.R1.4..2-R
DSP hardware version: Freescale BSC9131
Total channels: 60
Let me know if you have any other questions.
-Mark
Timothy,
Depends on what generation TA900e you have. If you have 2nd Gen (white unit) then only ports 3/4 can be used for PRI interfaces. If you have 3rd gen (Black unit) then 1-4 can be used for PRI interfaces but maximum of 2 can be configured depending on what p/n you ordered regarding number of DSPs, we sell a 30 and 60 count version.
If you do a show version it will show you have many you have like so:
Tiger#show version
ADTRAN, Inc. OS version R13.2.2.E
Mainline Version: ENM.17.94
P4 Changelist: 651357
Checksum: ccd996184c9dfa18573d4fbd589120e70d648470dd614b267ba6b072e7f8dcdd
Built on: Mon Aug 6 05:34:43 CDT 2018
Hardware version L.1.5.0.0-0
Boot ROM version R10.9.3.B1
Built on: Fri Apr 11 09:42:09 CDT 2014
Compatibility Version: 1
Copyright (c) 1999-2018, ADTRAN, Inc.
Platform: Total Access 908e (3rd Gen), part number 4243908F5
Serial number CFG1384365
Flash: 97120256 bytes DRAM: 509648896 bytes
Tiger uptime is 3 weeks, 3 days, 5 hours, 35 minutes, 53 seconds
slot 0, DSP 1
DSP software version: G3.R1.4..2-R
DSP hardware version: Freescale BSC9131
Total channels: 60
Let me know if you have any other questions.
-Mark