cancel
Showing results for 
Show  only  | Search instead for 
Did you mean: 
mrmac
New Contributor

With the TA908e (L5 version) with one DSP, how many PRI calls can be made simultaneously? 

Labels (1)
0 Kudos
1 Solution

Accepted Solutions
Anonymous
Not applicable

Re: DSPs

Jump to solution

mrmac:

You are correct. The L5 (single DSP) version is 30 SIP-to-TDM conversions, so technically you can do a full PRI (23 possible) as well as 7 of the FXS ports going all at once.

Regards,

Ronnie Colvin

Adtran Applications Engineering

--------------------------------

View solution in original post

0 Kudos
2 Replies
mrmac
New Contributor

Re: DSPs

Jump to solution

Is it 30 per DSP?

Anonymous
Not applicable

Re: DSPs

Jump to solution

mrmac:

You are correct. The L5 (single DSP) version is 30 SIP-to-TDM conversions, so technically you can do a full PRI (23 possible) as well as 7 of the FXS ports going all at once.

Regards,

Ronnie Colvin

Adtran Applications Engineering

--------------------------------

0 Kudos