The Adtran community holiday season is starting next week! The holiday period will span from December 21, 2024 to January 6, 2025. During this time, responses to feedback form submissions may be delayed. If you are encountering product issues, you can reach out to Adtran support at any time.
cancel
Showing results for 
Show  only  | Search instead for 
Did you mean: 
wcsengineering
New Contributor

924e to alarm system

Hi I have a customer who has analog lines going to a dialer panel for an alarm control system. Some calls come in and connect fine while others intermittently fail..looks like they dont get answered when the Adtran sends the call.

i have pasted my voice use configs etc below. If anyone can give me an idea why some calls work and others fail I would greatly appreciate it.

voice codec-list g711-only
codec g711ulaw
!
!
!
voice trunk T01 type sip
sip-server primary xx.xx.xx.xx
sip-server secondary xx.xx.xx.xx
max-number-calls 24
codec-list g711-only both
!
voice trunk T02 type analog supervision ground-start
modem-passthrough
rtp delay-mode adaptive
codec-list g711-only
!
voice trunk T03 type sip
busy all
sip-server primary xx.xx.xx.xx
max-number-calls 24
codec-list g711-only both
!
!
voice grouped-trunk MAIN-TG
trunk T01
trunk T03
accept NXX-NXX-XXXX cost 0
accept 1-NXX-NXX-XXXX cost 0
accept 411 cost 0
accept 611 cost 0
accept 911 cost 0
accept NXX-XXXX cost 0
!
!
voice grouped-trunk ANALOG
accept $ cost 0
!
!
voice user 1
connect fxs 0/1
no cos
password encrypted ""
no call-waiting
sip-authentication password encrypted ""
modem-passthrough
t38 max-rate 9600
codec-list g711-only
!

 

0 Kudos